The DLM-080 FUTURE Digital Recorder – User’s Manual
26.11.2004
28
11. DLM-080 – SPECIAL APPLICATIONS
11.1 DLM-080 AS PARAMETER RECORDER USED AT POULTRY
SLAUGHTERHOUSES.
Due to necessity to record technological parameters while slaughtering poultry it is possible to
configure the DLM-080 so that it meets requirements set in this case.
Typical system hardware configuration required for recording the above-mentioned parameters is
as follows:
- impulse sensor (counting number of pieces - quantity) – connection to 0/1 control input
- flowmeter (water meter) with 0..20mA current output; impulse sensor (counting number of
pieces - quantity) – connection to 0/1 control input
THE SETUP FUNCTIONS – SPECIFICATION
FUNC-
TION No.
TYPICAL
VALUE
PARA-
METER
RANGE
FUNCTION DEFINITION
COMMENTS
F00
0 0..31
Recorder number in the RS-485 network
F01
111 0..999
First digit of safety code for CLOCK setting
F02
111 0..999
Second digit of safety code for CLOCK setting
F03
888 0..999
First digit of safety code for SETUP setting
F04
888 0..999
Second digit of safety code for SETUP setting
F05
0 [min] 0..255
Recording printing frequency In case if F05=0 is set, printing
is interlocked.
F06
1 [min] 0..999
Digital recording frequency (the same for all
channels)
F07
Free
F08
Free
F09
Free
F10
Free
F11
Free
F12
Free
F13
Free
F14
0 0..999
The To time length for CHANNEL 1 (see Point
4.4)
F15
0 0..999
The To time length for CHANNEL 2 (see Point
4.4)
F16
0 0..999
The To time length for CHANNEL 3 (see Point
4.4)
F17
0 0..999
The To time length for CHANNEL 4 (see Point
4.4)
F18
0 0..999
The To time length for CHANNEL 5 (see Point
Vista de página 27